Visium CytAssist Spatial Gene Expression

Common questions related to the Visium CytAssist instrument, tissue preparation, CytAssist-enabled assay workflow, sequencing, and analysis using FFPE, Fresh Frozen, or Fixed Frozen tissues

General

  • What tissue types have been validated with the Visium CytAssist Spatial Gene Expression for Fixed Frozen assay?
  • Where are the validated stopping points in the Visium CytAssist Spatial Gene Expression for Fixed Frozen assay?
  • How long does the Visium CytAssist Spatial Gene Expression for Fixed Frozen assay take to perform?
  • Is healthy bone compatible with the Visium CytAssist Spatial Gene Expression for FFPE assay?
  • Is healthy skin compatible with the Visium CytAssist Spatial Gene Expression for FFPE assay?
See all 33 articles

CytAssist Instrument

  • Why is my Visium CytAssist instrument not communicating with the 10x Cloud?
  • How do I set-up a Network Shared Folder on my Visium CytAssist?
  • How are images exported from the Visium CytAssist instrument?
  • What USB drive format is compatible with the Visium CytAssist instrument?
  • Is it expected for the corner back bumpers of my Visium CytAssist instrument to not touch the bench top?
See all 29 articles

Tissue Preparation - FFPE

  • How do I transport my tissue slide to another facility when tissue has already been placed?
  • How should I fix and embed my tissue for Visium CytAssist for FFPE?
  • How is tissue preparation similar and different between Visium for FFPE (v1) and Visium CytAssist for FFPE?
  • What key steps are similar and different when running archived, hard coverslipped slides as compared to freshly placed FFPE sections?
  • What section thickness would we recommend to use with the Visium CytAssist for FFPE solution?
See all 14 articles

Tissue Preparation - Fresh Frozen, Fixed Frozen

  • How should I prepare my tissue for the Visium CytAssist Spatial Gene Expression for Fixed Frozen assay?
  • How do I ship Tissue Slides once fresh frozen or fixed frozen tissue sections have been placed?
  • How should I store Tissue Slides once fresh frozen or fixed frozen tissue sections have been placed?
  • How should I prepare fresh tissue for shipment?
  • What tissue section thickness is recommended for use with the Visium CytAssist for Fresh Frozen and Fixed Frozen assays?
See all 6 articles

Tissue Staining - FFPE

  • Can I use Xylene alternatives when performing Tissue Deparaffinization during the Visium CytAssist for FFPE assay?
  • How do I assemble and disassemble the Visium CytAssist Tissue Slide Cassette?
  • How many antibodies have we simultaneously tested following the IF Staining Demonstrated Protocol for FFPE tissues?
  • Can I use a PAP pen instead of Tissue Slide Cassette when performing immunofluorescence staining?

Tissue Staining - Fresh Frozen, Fixed Frozen

  • Is Immunofluorescence (IF) staining compatible with Fixed Frozen mouse tissue samples?
  • What tissue staining methods are compatible with the Visium CytAssist Spatial Gene Expression for Fresh Frozen assay?
  • How are the tissue sections fixed to Tissue Slides during the Visium CytAssist Spatial Gene Expression for Fresh Frozen (FF) workflow?

Imaging

  • What are the general imaging system requirements for running Visium CytAssist Spatial Gene Expression assays?

Library Construction

  • Why does my Visium CytAssist Spatial Gene Expression library have an extra high molecular weight peak?
  • Is it expected to have tissue remaining on the Tissue Slides after CytAssist-enabled RNA Digestion & Tissue Removal? 
  • How do I assemble and disassemble the Visium Slide Cassette? 
  • What does a good Visium CytAssist Spatial Gene Expression library look like?
  • What’s the expected range of Cq values that should be obtained when performing the Cycle Number Determination step with the Visium CytAssist Spatial Gene Expression assays?
See all 9 articles

Transcriptome Probe Sets

  • How does the Human Transcriptome Probe Panel v2 differ from the Human Transcriptome Probe Panel v1?
  • How are the human probes used in the Visium CytAssist Spatial Gene Expression solution similar to and different from the probes used in the Fixed RNA Profiling solution?

Sequencing

  • Do the index sequences used for Visium CytAssist Spatial Gene Expression libraries overlap with other index plates?
  • Can Visium CytAssist Spatial Gene Expression libraries be pooled with other 10x libraries?
  • How do I determine how many spots are covered with tissue to determine sequencing depth needed?
  • What are the minimum recommended sequencing specifications for Visium CytAssist Spatial Gene Expression libraries?

Software Analysis

  • How to Add Custom Probes to Cell Ranger and Space Ranger
  • Can I combine data from Visium CytAssist for FFPE and Visium for FFPE (direct placement) if I am using the Mouse Transcriptome v1 probe set?
  • Visium FRP probe gDNA background signal
  • What is the Visium CytAssist instrument?
footer-logo

Biology at True Resolution

About
  • Solutions
  • Technology
  • Company
  • Careers
  • Support
  • Community
  • Contact Us
Legal Notices
  • Privacy Policy
  • Terms of Use
  • Email Preferences
  • Other Legal Notices
Resources
  • Publications
  • Applications
  • Videos
Headquarters
  • +1 925 401 7300
  • +1 800 709 1208
  • info@10xgenomics.com
Social
©2018 10x Genomics. All Rights Reserved.
Sign up for product and event updates