Question: What are the best practices for dissociating tissue samples into single cells?
Answer: The following are some best practices to dissociate tissue into single cells :
1. Use a dissociation protocol that works for your tissue:
Tissue dissociation methods can impact the viability of the resulting cell suspension, so it's important to pick a dissociation protocol suitable for your tissue type. Various resources and publications outline common dissociation techniques for respective tissue types. Additionally, consider whether your cell type of interest has been known to be affected by warm enzymatic dissociation. See:
2. Unbiased tissue sampling:
Bias in cell-type composition can be introduced during tissue sampling, impacting sequencing results. This consideration is especially important for tissues structurally different like the brain and maybe less important for something more homogenous like the liver.
It is important to ensure the same region(s) are sampled across replicates or samples that will be compared. If starting with a large piece of tissue and only using a portion of the sample for single-cell sequencing, mix the dissociated tissue/cell suspension/nuclei suspension thoroughly before subsampling to reduce bias in cell types recovered.
3. Sample QC can provide information on tissue quality and dissociation method :
Some sample metrics can be informative on the quality of the starting tissue and dissociation method.
- Assessing the RIN of a tissue sample may be a way to exclude poor-quality samples; we recommend a RIN > 7
- Cell viability and debris can be indicative of inefficient dissociation or over digestion.
Issue |
Possible Causes |
Possible remediation |
Large pieces of tissue are still present |
Inefficient dissociation |
|
Lots of debris |
Inefficient dissociation or overdigestion |
|
Low cell viability |
The method is too harsh |
|
4. Perform a pilot when possible before proceeding with large sample batches:
If planning for a large experiment and handling a new sample type for the first time, it may be useful to run a pilot first to test the experimental workflow and gain confidence before proceeding to scale up. A pilot may also help inform which experimental condition may be more apt. See:
- Single Cell Gene Expression LT kit may be used to run a pilot experiment for sample prep optimization.
- I am running a pilot experiment to optimize sample preparation for single-cell assays; what metrics should I be looking at?
Products: Single Cell Gene Expression, Single Cell Immune Profiling, Fixed RNA Profiling Gene Expression